RELIABLE CFI-I EXAM LABS | CFI-I TESTING CENTER

Reliable CFI-I Exam Labs | CFI-I Testing Center

Reliable CFI-I Exam Labs | CFI-I Testing Center

Blog Article

Tags: Reliable CFI-I Exam Labs, CFI-I Testing Center, New CFI-I Practice Materials, Sample CFI-I Questions Pdf, Valid CFI-I Test Answers

To keep with such an era, when new knowledge is emerging, you need to pursue latest news and grasp the direction of entire development tendency, our CFI-I training questions have been constantly improving our performance and updating the exam bank to meet the conditional changes. Our working staff regards checking update of our CFI-I Preparation exam as a daily routine. So without doubt, our CFI-I exam questions are always the latest and valid.

We are a leading corporation in this line handling CFI-I study questions well with passing rate up to 98 and over percent, which is an unreachable goal for others. So our CFI-I preparation exam enjoys good sales for the excellent quality and reasonable prices in recent years. And we are so sure that we can serve you even better than you can imagine with our CFI-I learning guide since we are keeping on doing a better job in this career.

>> Reliable CFI-I Exam Labs <<

Verified NFPA Reliable CFI-I Exam Labs Strictly Researched by NFPA Educational Trainers

Perhaps you worry about the quality of our CFI-I exam questions. We can make solemn commitment that our CFI-I study materials have no mistakes. All contents are passing rigid inspection. You will never find small mistakes such as spelling mistakes and typographical errors in our CFI-I learning guide. No one is willing to buy a defective product. And our CFI-I practice braindumps are easy to understand for all the candidates.

NFPA CFI-I Exam Syllabus Topics:

TopicDetails
Topic 1
  • Occupancy Types: This section tests the abilities of exam-takers to assess fire and life safety systems for different occupancy types, including assembly, educational, and healthcare facilities.
Topic 2
  • Storage, Handling, & Use of Hazardous Substances and Materials: This module measures the skills of Fire Inspectors and includes recognizing hazardous conditions in equipment, processes, and operations.
Topic 3
  • Fire Protection Systems & Equipment: This section evaluates the skills of Fire Safety Technicians and focuses on determining the operational readiness of fire suppression systems, alarm systems, and portable fire extinguishers.
Topic 4
  • Administration: This section of the exam measures the skills of Fire Inspectors and covers the preparation of inspection reports, identifying the need for permits, and recognizing when plan reviews are required. It also involves investigating complaints, identifying applicable codes, and participating in legal proceedings. One key skill measured is communicating findings clearly in written reports.

NFPA Certified Fire Inspector I (CFI-1) Sample Questions (Q80-Q85):

NEW QUESTION # 80
Prior to conducting a fire flow test of a water distribution system, a responsible person from what department should be notified?

  • A. Highway department
  • B. Health department
  • C. Fire department
  • D. Water department

Answer: D

Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Fire Flow Tests:
Fire flow tests are conducted to determine the available water supply for firefighting and to ensure water distribution systems meet fire protection requirements.
Who Should Be Notified:
According to NFPA 291 (Recommended Practice for Fire Flow Testing and Marking of Hydrants), the water department must be notified prior to conducting fire flow tests.
This is because the water department oversees the water distribution system and needs to monitor for any disruptions, water loss, or pressure changes caused by the test.
Other Options Explained:
Option A (Fire department): Fire departments conduct or participate in the tests but do not need to be the primary department notified.
Option B (Highway department): Not involved in water system management.
Option D (Health department): Concerned with water quality, not water flow or system capacity.
Summary:
The water department must be notified prior to a fire flow test to ensure proper coordination and monitoring of the water distribution system.


NEW QUESTION # 81
When conducting a main drain test of a water-based fire protection system riser, what percentage of reduction in full flow pressure (as compared to the acceptance test or previously performed test) will trigger an investigation into the cause of the reduction?

  • A. 5 percent
  • B. 2 percent
  • C. 3 percent
  • D. 10 percent

Answer: A

Explanation:
A main drain test ensures that water flow and pressure in the system remain consistent. According to NFPA 25, Standard for the Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems:
A 5 percent or greater reduction in full flow pressure compared to prior tests triggers an investigation to identify and correct potential issues (e.g., obstructions or valve malfunctions).
Reference:
NFPA 25, Section 13.2.5.2: Pressure reduction thresholds for main drain tests.


NEW QUESTION # 82
All of the following information regarding a fire prevention inspection must be maintained by the AHJ EXCEPT:

  • A. The final deposition of all violations
  • B. The date of the service of notices
  • C. Responsible party at the inspection
  • D. A summary of the violations found

Answer: C

Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Fire Prevention Inspection Documentation:
Per NFPA 1 (Fire Code), Section 1.7.4, the AHJ (Authority Having Jurisdiction) must maintain specific records related to fire inspections to ensure compliance and provide a legal record.
Required Information Includes:
Date of the service of notices (A): Ensures proper communication and enforcement of violations.
Final disposition of all violations (B): Indicates whether violations were corrected or actions taken.
Summary of violations found (C): Documents what issues were identified during the inspection.
Why Responsible Party (D) is Excluded:
While the responsible party may be part of the inspection process, it is not a mandatory record to be maintained permanently by the AHJ under NFPA 1.
Summary:
The responsible party at the inspection is not a required record for fire prevention inspections.


NEW QUESTION # 83
Fire extinguishers having a gross weight not exceeding 40 lb (18.14 kg) shall be installed to which of the following criteria?

  • A. The top of the fire extinguisher is not more than 5 ft. (1.53 m) above the floor
  • B. The top of the fire extinguisher is not more than 5 ft. 6 in (1.68 m) above the floor
  • C. The bottom of the fire extinguisher is not more than 5 ft. (1.53 m) above the floor
  • D. The bottom of the fire extinguisher is not more than 5 ft. 6 in. (1.68 m) above the floor

Answer: A

Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Installation Height Requirements for Fire Extinguishers:
According to NFPA 10 (Standard for Portable Fire Extinguishers), Section 6.1.3.8, fire extinguishers with a gross weight not exceeding 40 lb (18.14 kg) must be installed so that the top of the extinguisher is not more than 5 ft. (1.53 m) above the floor.
Why This Height is Important:
A maximum height of 5 feet ensures accessibility to fire extinguishers for most people during emergencies.
Other Options Explained:
Option A (5 ft. 6 in): Exceeds the NFPA 10 limit and is too high for practical use.
Option C and D (Bottom of the extinguisher): NFPA 10 specifies the height based on the top of the extinguisher, not the bottom.
Summary:
Fire extinguishers with a weight not exceeding 40 lb must have their top installed no more than 5 feet (1.53 m) above the floor.


NEW QUESTION # 84
Which of the following operations would NOT require a permit issued by the AHJ?

  • A. The installation of an automatic fire suppression system
  • B. The maintenance of fire protection systems
  • C. The storage, use, and handling of flammable liquids
  • D. The use of mall areas for exhibits or displays

Answer: B

Explanation:
Comprehensive and Detailed Step-by-Step Explanation:
Permits and AHJ Oversight:
The Authority Having Jurisdiction (AHJ) issues permits for operations that:
Involve fire safety risks.
Impact public safety and property protection.
Require significant modifications, installations, or special activities.
Option A: Maintenance of Fire Protection Systems
Maintenance refers to routine tasks like inspections, testing, and minor repairs to keep fire protection systems functional.
NFPA 25 (Inspection, Testing, and Maintenance of Water-Based Fire Protection Systems) does not require a permit for standard maintenance.
Maintenance ensures compliance but does not typically involve new installations, modifications, or hazardous conditions that warrant AHJ approval.
Other Options Explained:
Option B (Use of Mall Areas for Exhibits or Displays):
Requires a permit due to potential fire hazards, obstructions to exits, and fire load introduced by exhibits.
Refer to NFPA 1, Chapter 20 for fire safety requirements in malls.
Option C (Storage, Use, and Handling of Flammable Liquids):
AHJ oversight is required as flammable liquids pose significant fire risks.
Refer to NFPA 30 (Flammable and Combustible Liquids Code).
Option D (Installation of an Automatic Fire Suppression System):
Requires a permit to ensure proper installation, design, and compliance with NFPA 13.
Summary:
Routine maintenance of fire protection systems does not require a permit because it involves keeping systems operational rather than introducing new installations, hazards, or modifications.


NEW QUESTION # 85
......

When we are in some kind of learning web site, often feel dazzling, because web page design is not reasonable, put too much information all rush, it will appear desultorily. Absorbing the lessons of the CFI-I study materials, will be all kinds of qualification examination classify layout, at the same time on the front page of the CFI-I study materials have clear test module classification, so clear page design greatly convenient for the users, can let users in a very short period of time to find what they want to study, and then targeted to study. Saving the precious time users already so, also makes the CFI-I Study Materials look more rich, powerful strengthened the practicability of the products, to meet the needs of more users, to make the CFI-I study materials stand out in many similar products.